Whichever system is employed, some knowledge is required of where certain fixtures are going so that extra reinforcement can be added to allow heavy items such as kitchen cupboards or bathroom basins to be properly supported.
Electrical wiring and plumbing pipe work will also be run through the wall during its construction and it is essential that everything will be in the right place when the room is finished as correcting even the smallest mistake afterwards, such as adding an extra light switch, is time consuming. Large mistakes can involve having to take down entire sections of plasterboard - a messy process if the board has already been plastered.
When building a stud wall that will be used as the wall of a shower cubicle special waterproof board should be used. Aquapanel is a glass mesh reinforced, cement based board that can withstand being immersed continually in water and therefore avoids the problem of having to rip down tiles to replace plasterboard should the shower develop a leak.

The most common type of internal wall is the wooden stud-partition. Here lengths of 3"x2" or 4"x2" (75x50mm or 100x50mm) are made into a frame which runs across floor, walls and ceiling. Studs are then attached between head (ceiling) and sill (floor) plates at regular intervals and noggins skew-nailed between them to stiffen them. Doorways are allowed for with cut outs in the sill plate and extra studs above the door. Extra noggins or sheets of wood can be attached between studs to allow for heavy fixtures.
The metal stud construction system uses the same basic idea as wood, but the material is plated steel sheet extruded into lengths of a C-profile shape which can be screwed together with self-tapping screws. It is available in lengths of 2.4m to 4.2m (8' to 14') and widths of 48, 60, 70 and 146mm. Again a frame is made around the walls, floor and ceiling and studs added, however there are no noggins between the studs with this system. For fixing heavy items special fixing channels are available. Once finished the partition is plasterboarded using only drywall screws; nails cannot be used.

Cellular core partitioning consists of two sheets of plasterboard with a honeycombed cardboard core, effectively forming an entire wall section in one part. As before an outline wooden frame of 2" PAR is created with locating blocks added where the edge of the partition meets the frame. The cellular core sheets are then slotted into place and screwed or nailed to fix them. Where partition sheets meet at a corner or T-joint, extra battening needs to be inserted into the sheets to allow a solid fixing between them.
|